Product line Ist Bureau
№ |
Product name |
Product description |
1 |
Wired device for weather conditions measuring
|
Measuring weather conditions gauges: humidity, pressure, temperature. Transferring data by TCP/IP protocol. Specifications: supply voltage 5 V, temperature sensor accuracy 0.01°С, humidity sensor accuracy 1%, loop powered <15 mA, absolute error ± 0.5 °C (at 25 °C), absolute error ± 3%, 3.8 V is the power supply voltage of the transmitting module, pressure measurement range 30.. 110 kPa, communication range 800.. 1000 m, frequency range of the transmitting module 2.4 GHz, pressure sensor resolution 1 Pa, sensor calibration mode - built, data transmission interface RS-485, absolute error 0...65 ° C ± 100 Pa, humidity sensor hysteresis 1%, temperature measurement range -40.. +85 °C, humidity measurement range 0...100%, case material stainless steel. |
2 |
Wireless device for weather conditions
|
Measuring weather conditions gauges: humidity, pressure, temperature. Transferring data by different wireless networks: cell, wi-fi. Specifications: supply voltage 5 V, temperature sensor accuracy 0.01°С, humidity sensor accuracy 1%, loop powered 20 mA, absolute error ± 0.5 °C (at 25 °C), absolute error ± 3%, 3.8 V is the power supply voltage of the transmitting module, pressure measurement range 30.. 110 kPa, communication range 800.. 1000 m, frequency range of the transmitting module 2.4 GHz, pressure sensor resolution 1 Pa, sensor calibration mode - built, data transmission interface RS-485, absolute error 0...65 ° C ± 100 Pa, humidity sensor hysteresis 1%, temperature measurement range -40.. +85 °C, humidity measurement range 0...100%, case material ABS plastic, weight 0,2 kg |
3 |
Not-inertial Atmospheric wind measurement device
|
Measuring wind parameters: speed, direction. Specifications: supply voltage 12..24 V, heating power 3W, power consumption 1W, power supply voltage of the transmitting module 20 mA, absolute error ± 0.5 °C (at 25 °C), absolute error ± 3%, speed accuracy ± 2%, resolution on the direction 1°, speed resolution 0,01m/s, data transmission interface RS-485/RS-23, weight 0,68 kg, temperature measurement range -40.. +70 °C, case material ABS plastic |
4 |
Measuring gamma wave radiation gauges
|
Radiometeorological scanner Advantages of the sensor: made on the basis of a single-board mini computer based on the LINUX operating system; wide range of wind speed measurement; resistance to salt mist, increased chemical resistance. Specifications: supply voltage 7..14 V, current consumption 2A, data transmission interface RS-485, the range of measuring the power of the radio signal 24...1766 MHz, temperature measurement range -40.. +85 °C, humidity measurement range 0...100%, pressure measurement range 30.. 110 kPa, weight 1,2 kg, case material stainless steel. |
5 |
Joined devices: humidity, pressure, temperature and wind. Wired and wireless installation. |
Transferring data by wired or different wireless networks: cell, wi-fi. |
6 |
Vertical atmospheric array (10 gauges)
|
The meteorological integrated sensor (MCD) is designed to measure, process and output data on atmospheric parameters: pressure, humidity and temperature on 10 meters layer up to surface or water, as well as data transmission via wired and wireless communication lines using the Modbus RTU protocol. The sensor is powered by an electrical network or a household battery. The required number of meteorological complex sensors can be combined into a meteorological garland using a connecting cable to obtain vertical profiles of meteorological parameters depending on the required height. Specifications: supply voltage 5 V, temperature sensor accuracy 0.01°С, humidity sensor accuracy 1%, loop powered <15 mA, absolute error ± 0.5 °C (at 25 °C), absolute error ± 3%, the power supply voltage of the transmitting module 3.8 V, pressure measurement range 30.. 110 kPa, communication range 800.. 1000 m, frequency range of the transmitting module 2.4 GHz, pressure sensor resolution 1 Pa, sensor calibration mode - built, data transmission interface RS-485, absolute error 0...65 ° C ± 100 Pa, humidity sensor hysteresis 1%, temperature measurement range -40.. +85 °C, humidity measurement range 0...100%, case material stainless steel.
|
7 |
Vertical underwater acoustics system (two vertical array 20 gauges each), passive and multistatic mode |
Matched field processing for passive and multi static detection underwater obstacles and terrorist treats in shallow waters. |
8 |
AIS |
Transferring and Receiving data from ships on the sea. |
9 |
AIS receiver |
Receiving data from ships on the sea. |
10 |
ADS-B receiver |
Receiving data from aircraft's on the sky. |
11 |
Network hub |
Receiving, processing and storing data from different sources of data. Transferring data by wired or wireless networks: cell, Wi-Fi, satellite. |